Legacy Open Mesh: Switch firmware release notes
Topic
This article lists firmware release notes for Datto Switches.
Environment
- Datto Switches
Description
Index
- Release 2018-10-15
- Release 2018-07-11
- Release 2018-01-30
- Release 2017-09-11
- Release 2017-08-02
- Release 2017-07-11
- Release 2017-04-12
- Release 2017-03-23
- Release 2016-11-14
- Release 2016-10-11
- Release 2016-10-01
1.03.24 - Released October 15, 2018
Bug Fixes
- Resolved an issue where wrong configurations caused a memory leak
- Resolved an issue for OMS48 switches that caused check-ins to miss scheduling
1.03.19 - Released July 11, 2018
New Features - CloudTrax support coming soon
- Auto Voice VLAN: Added LLDP-MED functionality that allows a switch to broadcast the Voice VLAN configuration
- SNMP Trap: Added functionality that allows a switch to send SNMP alert messages
- Jumbo Frames: Added functionality that allows a switch to send Ethernet frames larger than 1500 bytes
- LED Dark Mode: Added functionality that allows a port to operate with its LED disabled
Improvements
- Added functionality that lets the connection keeper use TCP keep-alive messages.
- Updated certificate for cloud connections
Bug Fixes
- Corrected the Jumbo Frame range utilized by switches
- Resolved an issue where SNMP versions were reversed
- Resolved an issue where a fiber port failed to operate under dark mode
- Reduced the number of times NTP server is called to once per hour
- (S24v3 only) - Resolved an issue that prevented the 10GB fiber port from achieving a link
- (S24v3 only) - Fixed an issue where a 10GB SFP module could not properly trunk
- (S24v3 only) - Resolved an issue that prevented port speed settings from being saved
- (S24v3 only) - Fixed an issue where control packets could not trap to the CPU on port 26
1.03.15
S24v3 initial firmware release
1.03.11 - Released January 30, 2018
Bug Fixes
- Get time from fallback CloudTrax server when DNS fails
1.03.09 - Released September 11, 2017
Bug Fixes
- Improves reliability of check-in if using the wrong DNS
1.03.07 - Released August 2, 2017
New Features
- Supports new line of switches S8-L and S24-L
Bug Fixes
- Updated local SSL certificates to ensure continued check-in with CloudTrax into the future
1.03.05 - Released July 11, 2017
New Features
- LLDP (not LLDP-MED)
- Diagnostic features (Cable Test / Ping / Traceroute)
Bug Fixes
- FIX: Switch could hang when setting a rate limit on a port
1.02.07 - Released April 12, 2017
Bug Fixes
- Addresses a condition where the Switch stops checking in
- Improvements to upgrade process and install validation
1.02.05 - Released March 23, 2017
New Features
- Auto-detect uplink port
- Port (and overall) forwarding table
- Add protection for PVID and Untagged VLANs, once we can autodetect uplink
- Security:
- MAC ACL/ ACE
- IPv4 ACL/ ACE
- Port Isolation
- Bytes per port
- Data (all tx and rx counters)
- Graph
- QoS
- Enable/ disable
- DSCP -> CoS mapping
- CoS -> Switch queue mapping
- Trust incoming classification or set own
- Voice VLANs
- Enable/ Disable
- VLAN ID
- OUI list: Default and add new ones
- Enable disable voice VLAN
- Set CoS mode
1.01.01 - Released November 14, 2016
New Features
- Spanning Tree Protocol (STP)
- IGMP Snooping
- PoE Reset (instant)
- Link Speed and Mode
- Rate Limiting (Tx/Rx)
- Flow Control
- Link Aggregation
- Port Mirroring
- PVID (Native VLAN) and Untagged VLANs
1.00.02 - Released October 11, 2016
New Features
- Ability to view per-port PoE consumption
- Dynamic port controls from switch image within the switch pane:
- Identify and click through to Open Mesh AP, when connected directly
- Identify and list devices in the port forwarding table, when not directly connected to an OM AP
1.00.00 - Released October 1, 2016
New Features
- Cloud management and configuration via CloudTrax
- Configurable scheduled firmware upgrades, by switch model
- Monitoring Features:
- Total Power
- Current Usage/ Available Power
- Device Name
- MAC Address
- IP Address
- Gateway IP Address
- Total and Active Ports (e.g., 2/10)
- Firmware version
- Uptime
- PoE Budget
- Configuration Features:
- Enable/ Disable PoE
- PoE Type: Manual or Auto
- Priority (when Type set to Auto)
- Power limit (when the type is set to manual)
- Number and Description
- Status
- Enable/ Disable Link
- Allowed VLANs
- PoE configuration
- SNMP configuration (read-only)
- Per Port Configuration
- Local Management (Web GUI, telnet, SSH): Disabled on first cloud check-in, to prevent configuration conflicts with CloudTrax.