MP60 features & specifications

Topic

This article provides the hardware specifications and region availability for the Datto MP60.

Environment

  • Datto Managed Power MP60

Description

The MP60 provides six fully-managed and monitored power ports, as well as two USB Type-A and two USB Type-C ports. The product is for use in monitored environments such as IT closets or offices and deployment in conjunction with the Datto Networking cloud portal for configuration and troubleshooting.

Device Layout

mceclip0.png
Figure 1: Datto MP60

Technical Specifications

Outlets Six surge-protected outlets
Specification Spec
Voltage 100-125V 15A 60 Hz input
Idle Power Draw 4W
Ports Two 2.1A USB-C and two 1A USB-A charging ports.
WiFi 2x2 802.11n WiFi
Dimensions 14.75 in. X 4 in. X 1.5 in.
Weight 1.79 lbs / .81 Kg

Environmental Conditions and Surge Protection Ratings

Environmental Conditions

  • Indoor use only
  • Altitude up to 2000m
  • Temperature 5° C to 40° C
  • Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40° C
  • MAINS supply voltage fluctuations up to ±10% of the nominal voltage
  • Pollution Degree 2

Surge Protection Ratings

  • Energy Capacity: 4000J
  • Clamping Voltage: 330V
  • Maximum Spike Voltage: 6000V
  • Worst Case Response Time: 25 nS

Regulatory Notes

  • Disconnection means: Type 1B
  • Pollution degree: 2
  • Rated impulse voltage: 1500V (rated up to 125V)
  • Automatic action: 100,000 cycles
  • Ratings for supply and loading
  • AC Input: AC ~100-125V 15A maximum 60 Hz 1875W
  • USB Output: Total maximum for USB port: 5V / 6.2A
  • Total maximum for power outlets: 15.5A AC 100-125V Resistive 10A maximum each

Product Operation

  • As a safety measure, any port measuring 10A or higher will disable itself. You can re-enable ports by logging in to the Datto Networking portal (networking.datto.com) and managing the port settings for that power strip.
  • The main plug or appliance coupler acts as the disconnecting device.
  • Do not place the MP60 in a spot where it is difficult to disconnect the main plug or appliance coupler.
  • The pinhole reset will reset the device's CPU and NIC; it will not disconnect power to the outlets.
  • The soft switch will disable power to the outlets.
  • Clean only with a dry cloth.

Product Certifications

The MP60 carries the following certifications:

  • ETL US safety UL60950
  • CSA 22.2 Canadian UL60950
  • UL498
  • UL60950
  • UL60730
  • UL1449
  • UL61010
  • FCC/IC
  • Rohs